EMIA-Expert Carbon/Sulfur Analyzer

 

Overview

High Performance Model: EMIA-Expert
For expert analyst demanding the greatest accuracy and precision

The EMIA-Expert Carbon/Sulfur Analyzer is based on HORIBA’s widely respected expertise in Non-Dispersive Infrared (NDIR) technology.
It offers improved the cleaning efficiency, enhanced user-friendly software, durability, operability and maintenance to ensure efficient measurements and its shortened cycle time accelerates your development and manufacturing speed.

Advanced functions for EMIA-Expert

EMIA-Expert has advanced functions to realize high performance analysis in addition to standard functions of EMIA-Pro.

High Performance Purifier Unit for Carrier Gas

Enables measurement of ultra-low carbon concentration with high accuracy by eliminating hydrocarbon impurities in the carrier gas.

High Performance Heating Filter Unit

Samples which are moist or that generate water during analysis may cause a small error for the analysis of sulfur. This is due to the evolved water absorbing the SO2 gas. Using the heating filter, the absorption of SO2 by moisture is prevented, and highly accurate sulfur analysis is guaranteed.

Features

Long MTBM (Mean Time Between Maintenance)

The unique newly-developed cleaning mechanism (patent pending) clears the dust in the furnace, allowing the operator to continue to use the EMIA-Expert/Pro without maintenance cleaning for up to 200 measurements*.
* It depends on sample and measurement condition

Before measurement     

After 200 measurements

High Throughput

EMIA Series can complete one measurement cycle, “measurement-display result-cleaning”, in 70 seconds (i.e. about 50 samples/hour)

Fast & Easy Maintenance

With the latest innovations the cleaning time for the EMIA Series instruments is  typically half of that of our conventional models. The flat design around the crucible stand and simple design around the furnace also simplify user access for cleaning.

Flat design around the crucible stand

Advanced Operation software

A critical focus was to ensure that the EMIA-Expert/Pro Series was “easy-to-use”. In particular, we focused on the layout, operating menus and functions.
We have included a self-diagnostic monitor checking capability to check the status of the connected device, an alarm function and we have expanded 3 navigators to facilitate daily operation.

 

 

Analysis Navigator

This function uses the recommended best measurement flow and operating condition based on our experience.

Troubleshooting Navigator

Maintenance Navigator

Periodic preventive maintenance work navigator by videos and photos.

Specifications

Contents

EMIA-Expert

Required sample amount

1g ± 0.1g

Typical Meas. time

70 seconds/cycle

Carbon

Meas. Range (m/m)

0.6 ppm - 10.0%

Blank accuracy

σn-1≦ 0.3 ppm

Sulfur

Meas. Range (m/m)

0.6 ppm - 1.0%

Blank accuracy

σn-1 ≦ 0.3 ppm

Sample meas. Accuracy

Carbon

σn-1 ≦ 0.3 ppm(less than 20 ppm) 
σn-1 ≦ 1.0 ppm or RSD≦0.5%(more than 20 ppm)

Sulfur

σn-1 ≦ 0.3 ppm(less than 20 ppm) 
σn-1 ≦ 1.0 ppm or RSD≦0.75%(more than 20 ppm)

Utility

Carrier gas

Oxygen 
(Purity; 99.5%, Pressure; 0.3-0.33 MPa)

Operation gas

Nitrogen 
(Purity; 99.5%, Pressure; 0.35-0.38 MPa)

Power

200/220/240V, 50/60Hz, 5kVA

Dimensions

Main unit*

500(W) x 725(D) x 710(H) mm

Purifier unit

160(W) x 560(D) x 512(H) mm

Mass

Main unit

approximately 134 kg

Purifier unit

approximately 21 kg

Data processing and operation

USB data communication with PC Windows 8.1
Touch panel or Key board and mouse operation

Model name

EMIA-20E: Carbon/Sulfur
EMIA-21E: Carbon
EMIA-22E: Sulfur

Note) "ppm" is equal to mg/kg.

*Except piping parts, projection parts (D:79mm) and flow meter on the back side.

Schematics

 
 
 

EMIA-Pro Carbon/Sulfur Analyzer

 

Overview

Standard Model: EMIA-Pro
Enables everyone to become a professional analyst

The EMIA-Pro Carbon/Sulfur Analyzer is based on HORIBA’s widely respected expertise in Non-Dispersive Infrared (NDIR) technology.
It offers improved the cleaning efficiency, enhanced user-friendly software, durability, operability and maintenance to ensure efficient measurements and its shortened cycle time accelerates your development and manufacturing speed.

 

Long MTBM (Mean Time Between Maintenance)

The unique newly-developed cleaning mechanism (patent pending) clears the dust in the furnace, allowing the operator to continue to use the EMIA-Expert/Pro without maintenance cleaning for up to 200 measurements*.
* It depends on sample and measurement condition

 Before measurement

After 200 measurements

High Throughput

EMIA Series can complete one measurement cycle, “measurement-display result-cleaning”, in 70 seconds (i.e. about 50 samples/hour)

Fast & Easy Maintenance

With the latest innovations the cleaning time for the EMIA Series instruments is typically half of that of our conventional models. The flat design around the crucible stand and simple design around the furnace also simplify user access for cleaning.

Flat design around the crucible stand

Advanced Operation software

A critical focus was to ensure that the EMIA-Expert/Pro Series was “easy-to-use”. In particular, we focused on the layout, operating menus and functions.
We have included a self-diagnostic monitor checking capability to check the status of the connected device, an alarm function and we have expanded 3 navigators to facilitate daily operation.

 

 

* Analysis Navigator

This function uses the recommended best measurement flow and operating condition based on our experience.

* Troubleshooting Navigator

Automatic diagnosis system and troubleshooting navigator.

* Maintenance Navigator

Upgradable

The customer can extend the system’s functionality at any time, even after installation, depending upon their needs. Upgrades include: 
* Carrier gas purifier for ultra-low concentration carbon measurement 
* Auto-sampler (20 positions)
* Halogen trap unit

Specification

Contents

EMIA-Pro

Required sample amount

1g ± 0.1g

Typical Meas. time

70 seconds/cycle

Carbon

Meas. Range (m/m)

1.6 ppm - 6.0%

Blank accuracy

σn-1 ≦ 0.8 ppm

Sulfur

Meas. Range (m/m)

2.0 ppm - 1.0%

Blank accuracy

σn-1 ≦ 1.0 ppm

Sample meas. Accuracy

Carbon

σn-1 ≦ 2.0 ppm 
or RSD≦1.0%

Sulfur

σn-1 ≦ 2.0 ppm 
or RSD≦1.5%

Utility

Carrier gas

Oxygen 
(Purity; 99.5%, Pressure; 0.30-0.33MPa)

Operation gas

Nitrogen 
(Purity; 99.5%, Pressure; 0.35-0.38MPa)

Power

200/220/240V, 50/60Hz, 5kVA

Dimensions

Main unit*

500(W) x 725(D) x 710(H) mm

Mass

Main unit

approximately 134 kg

Data processing and operation

USB data communication with PC Windows 8.1
Touch panel or Key board and mouse operation

Model name

EMIA-20P: Carbon/Sulfur
EMIA-21P: Carbon
EMIA-22P: Sulfur

Note) "ppm" is equal to mg/kg.

*Except piping parts, projection parts (D:79mm) and flow meter on the back side.

Schematics

EMIA-V2 series Carbon/Sulfur Combustion Analyzer

 

Overview

The EMIA-V2 series measures carbon and sulfur extracted during combustion in a programmable High Frequency furnace without conversion. Combustion control is achieved through the use of the high-frequency induction furnace method. Appropriate heat-control in accordance with the analysis objective enables high-precision analysis for all types of samples. A variety of models allow you to select the furnace system that is best suited to your target samples and application.

  • EMIA-920V2 C/S analyzer: High performance analyzers with outstanding accuracy of less than 0.3ppm
  • EMIA-320V C/S analyzer: Standard performance analyzers for wide range of applications.

Features

  • "Auto cleaner" mechanism reduced maintenance works
    (Standard for 920V, Option for 320V2)

  • The Dust filter heating mechanism provides stable analysis with extremely low gas absorption
    (920V2 only)

  • Real-time simultaneous detection of CO/CO2/SO2 without an oxidizing (COCO2) or SO3 trapping reagents.

  • Wide variety of self diagnostics

  • Programmed temperature curve for optimizing combustion.

  • Choose from standard or wide range models to suit your application requirements.

     

Specification

EMIA-920V2 series 
EMIA-920V2:Simultaneous carbon/sulfur analysis 
EMIA-921V2:
Carbon analysis

EMIA-922V2: Sulfur analysis

Principle:
NDIR/ Non Dispersive Infrared Gas Anaryzer

High-frequency furnace method in oxygen flow

Range: Carbon: 0-6,0%, Sulfur: 0-1,0%
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Carbon: 

Concentration less than 20 ppm >>> σn-1≦0.3 ppm
Concentration higher than 20 ppm >>> σn-1≦1 ppm or RSD ≦0.5%

Sulfur:
Concentration less than 20 ppm >>> σn-1≦0.3 ppm
Concentration higher than 20 ppm >>> σn-1≦1 ppm or RSD ≦0.75%

Sample weight: 1,0g standard

Sensitivit: 0,01ppm 

Analysis time: Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

Calibration
One-point or multi-point calibration using standard sample 


Combustion furnace method/furnace structure
High-frequency induction furnace method with combustion control function (patent pending)

Anode output: 2300W
Frequency: 20MHz 
Plate current: Settable up to 500mA  
Automatic control possible (10 slopes maximum) 
Constant dust filter heating function 

Operation gas
Oxygen purity: More than 99.5%

Dry air or nitrogen: Supply pressure 0.35MPa

Functions
Interrupt analysis

Self diagnosis
Data storage(Measurement results)
Traceability of calibration curve and measurement conditions
Statistic calculation
Maintenance navigator

Automatic cleaning mechanism: Built-in as standard

Oxygen gas purifying unit: Built-in as standard

Power
Main unit: AC200/220/240V  5kVA  50/60Hz

PC: AC100V, 120/200/220/240V  0.5kVA  50/60Hz

Dimensions: 560(W)×927(D)×950(H)mm Approx.170 kg
--------------------------------------------------------------------------------------------------------

EMIA-320V2 series
EMIA-320V2:Simultaneous carbon/sulfur analysis

EMIA-321V2:Carbon analysis
EMIA-322V2:Sulfur analysis

Principle: 
NDIR/ Non Dispersive Infrared Gas Anaryzer

High-frequency furnace method in oxygen flow

Range:Carbon: 0-6.0%, Sulfur: 0-1.0%
Up to 100% wt is possible by decreasing the sample weight.

Accuracy
Carbon: σn-1≦2 ppm or RSD≦1.0%

Sulfur: σn-1≦2 ppm or RSD≦1.5%

Sample weight: 1,0g standard

Sensitivity: 0,1ppm 

Analysis time
Normally 30 to 60 seconds(after combustion),varies according to the characteristics of the samples

Calibration: One-point or multi-point calibration using standard sample 

Combustion furnace method/furnace structure
High-frequency induction furnace method with combustion control function (patent pending)

Anode output: 2300W
Frequency: 20MHz 
Plate current: Settable up to 500mA  
Automatic control possible (10 steps maximum) 

Operation gas
Oxygen purity: More than 99.5%

Dry air or nitrogen: Supply pressure 0.35MPa

Functions
Interrupt analysis

Self diagnosis
Data storage(Measurement results)
Memory of calibration curve and measurement conditions
Statistic calculation

Automatic cleaning mechanism: Option

Oxygen gas purifying unit: Option

Power
Main unit: AC200/220/240V  5kVA  50/60Hz
PC: AC100V, 120/200/220/240V  0,5kVA  50/60Hz

Dimensions: 560(W)×885(D)×820(H)mm Approx.170 kg

Schematics

EMIA-Vseries Dimensional outline drawing (mm)
 
 
 

EMIA-8100 series Carbon/Sulfur Combustion Analyzer

 

Overview

EMIA-8100 series equipped with electrical resistance furnace measures carbon and sulfur contained in such inorganic substances as ceramics and cement, such fuels as coal and heavy oil, and such high-purity metals and electronics materials as pure iron and nonferrous metals.

Temperature raising functions and automated opening and closing function of the sample-insertion aperture provide efficiency combustion and highly precise analyses.

Features

  • Temperature increase function allows setting up to ten combinations of temperature/time
  • The pressurised oxygen combustion method expands the range of applications
  • Enable the separation analysis of inside and outside C/S
  • Automatic opening/closing mechanism of sample door permits simplification of analysis work
  • Two combustion tubes make highly efficient and highly accurate analysis are possible

Specification

Model

EMIA-8100

Simultaneous carbon/sulfur analysis

EMIA-8110

Carbon analysis

EMIA-8120

Sulfur analysis

Principle

NDIR/ Non Dispersive Infrared Gas Anaryzer

 

Tube-shaped electric resistance furnace method 
in oxygen flow

Range

Carbon: 0-6,0%

 

Sulfur: 0-1,0%

 

Up to 100% wt is possible by 
decreasing the sample weight.

Accuracy

Carbon

 

σn-1≦0.00015 %(m/m) or CV≦0,75%

 

Sulfur

 

σn-1≦0.0002 %(m/m) or CV≦2,0%

Sample weight

1,0g standard

Sensitivity

0,01ppm

Analysis time

Normally 40 to 60 seconds(after start combustion)
variesaccording to the characteristics 
of the samples

Calibration

One-point or multi-point calibration 
using standard sample

Combustion furnace
method/furnace structure

Tube-shaped electric resistance furnace with
temperature increase function and 
oxygen pressure combustion 

Operating temperature range: 400 to 1450°C

Temperature increase function: Settable up to 
1450°C (10 slopes maximum)

Operation gas

Oxygen purity: More than 99.5%
Dry air or nitrogen: Supply pressure 0.35MPa

Automatic cleaning mechanism

No available

Oxygen gas 
purifying unit

Option

Power

Main unit: AC200V, 220V, 240V  5kVA  50/60Hz
PC: AC100V  0,5kVA  50/60Hz

Dimensions

690(W)×880(D)×577(H)mm Approx.100 kg

Schematics

EMIA-8100 series Dimensional outline drawing (mm)
 
 
 
 

Open chat